Axpert MAX II 8KW TWIN Off Grid Inverter Main Features
Model | Axpert MAX II TWIN 8K |
Rated Power | 8000VA/8000W |
Parallel Capability | YES, 6units |
INPUT | |
Voltage | 230 VAC |
Selectable Voltage Range | 170-280 VAC (For Personal Computers) ; 90-280 VAC (For Home Appliances) |
Frequency Range | 50 Hz/60 Hz (Auto sensing) |
OUTPUT | |
AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
Surge Power | 16000VA |
Efficiency (Peak) | 93% |
Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
Waveform | Pure sine wave |
DC Voltage | 12VDC ± 5% |
BATTERY | |
Battery Voltage | 48 VDC |
Floating Charge Voltage | 54 VDC |
Overcharge Protection | 66 VDC |
SOLAR CHARGER & AC CHARGER | |
Solar Charger Type | MPPT |
Maximum PV Array Power | 8000W (4000W*2) |
MPPT Range @ Operating Voltage | 90 ~ 450 VDC |
Maximum PV Input Current | 27A*2 (MAX 40A) |
Maximum PV Array Open Circuit Voltage | 500VDC |
Maxmum Solar Charge Current | 150A |
Maximum AC Charge Current | 120A |
Maximum Charge Current | 150A |
PHYSICAL Dimension | |
Dimension, D x W x H (mm) | 158.4 x 503.6 x 530.8 |
Net Weight (kgs) | 20 |
Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
OPERATING ENVIRONMENT | |
Humidity | 5% to 95% Relative Humidity(Non-condensing) |
Operating Temperature | -10°C to 50°C |
Storage Temperature | -15°C to 60°C |
STANDARD | |
Compliance Safety | CE |
Voltronic Axpert MAX II TWIN. New fourth generation 8000W and 48V solar inverter. This new equipment includes new techniques, this new model incorporates a Wi-Fi function, this allows you to carry out monitoring from your mobile through the mobile application.
Double mppt of 500v and 150A.
The new axpert max hybrid inverter has two independent inputs of up to 500v and 150 amps to connect up to 4000w in solar panels in each of them. With the two inputs to the maximum we have a photovoltaic field of 8000w to power consumption and charge batteries. The starting range has been decreased and at only 90 volts input the mppt will already work to generate solar energy.
The inverter has an 150 amp AC charger for cloudy days
The 80 amp battery charger of this hybrid allows that if the battery ever dies due to bad weather the hybrid inverter can use the source of a generator or electrical network to charge it in a few hours. If the load source is a generator, it must be a low harmonic distortion inverter. Non-inverter generators may not be supported by the equipment as having correct margins to run.
All-in-one inverter with LCD where you can see all the data of the solar installation.
On this screen you will monitor the entire system in an easy and intuitive way, voltage and power of the solar panels, consumed power, frequency and output voltage, as well as being able to program a multitude of options and operating priorities. Very intuitive to use.
It includes software for windows and linux where you can monitor the system from a pc to modify values, download historical records, set alarms, …